Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Intervalo de año de publicación
1.
Rev Fac Cien Med Univ Nac Cordoba ; 79(3): 298-300, 2022 09 16.
Artículo en Español | MEDLINE | ID: mdl-36149080

RESUMEN

Background: The phenomenon of deformation of devices for closure of intracardiac defects in catheterization has been reported, but not of devices for closure of patent ductus arteriosus. Objective: to report a case of deformation of a relatively new type of device for closure of patent ductus arteriosus. Methods: report an adult with hypertensive patent ductus arteriosus and a positive balloon occlusion test will be presented, in whom the occlusion was attempted with an Occlutech®-PDA device. Results: Upon delivery, the device took the shape of a "horn" instead of a "champagne cork" (usual appearance), so it was extracted prior to it is release and the procedure was carried out with another device. Conclusion: To our knowledge, no deformation during the delivery transcatheter of the Occlutech®-PDA device has been published. Adverse events related to new technologies, as in our case, should be reported as soon as possible, since it can help manufacturers to improve their quality and provide greater safety to patients.


Introducción: Existen comunicados sobre el fenómeno de la deformación de dispositivos oclusores de defectos intracardíacos durante el cateterismo, pero no acerca de los dispositivos oclusores para el conducto arterioso persistente. Objetivo: comunicar un caso de deformación de un relativamente nuevo tipo de dispositivo oclusor de conducto arterioso persistente. Método: se presenta un paciente adulto con conducto arterioso persistente hipertensivo y prueba de oclusión con balón positiva, en quien se intentó ocluirle con un dispositivo Occlutech®-PDA. Resultado: al momento de la entrega, el dispositivo adoptó la "forma de claxon" en lugar de "corcho de champagne" (apariencia habitual), motivo por el que fue retirado previo a su liberación y el procedimiento fue llevado a cabo con otro dispositivo. Conclusión: hasta donde conocemos, no hay comunicados acerca de deformación del dispositivo Occlutech®-PDA durante su implante mediante cateterismo. Los eventos adversos relacionados a nuevas tecnologías, como el presentado en este caso, deben ser comunicados tan pronto como sea posible, ya que esto puede ayudar a los fabricantes a mejorar su calidad y proveer mayor seguridad a los pacientes.


Asunto(s)
Conducto Arterioso Permeable , Dispositivo Oclusor Septal , Adulto , Cateterismo Cardíaco/efectos adversos , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/etiología , Conducto Arterioso Permeable/cirugía , Humanos , Diseño de Prótesis , Resultado del Tratamiento
2.
Rev. ecuat. pediatr ; 18(1): 35-36, 201706.
Artículo en Español | LILACS | ID: biblio-996633

RESUMEN

El tratamiento clásico del secuestro pulmonar ha sido mediante cirugía con lobectomía o neumonectomía, actualmente hay alternativas de tratamiento menos invasivas tales como el cateterismo. Objetivo: Comunicar el tratamiento percutáneo de un secuestro pulmonar gigante en un lactante. Método: Estudio descriptivo. Historia clínica y base de datos del laboratorio de cateterismo. Resultados: lactante de 1,5 meses de edad en quien se realizó tratamiento por cateterismo de un gran secuestro pulmonar extralobar sintomático con un dispositivo tipo tapón desde la arteria femoral. Como complicaciones presentó síndrome de respuesta inflamatoria sistémica que requirió cuidados intensivos y disminución del pulso femoral que se trató con enoxaparina. Tiempo de internación: 10 días. Seguimiento: 2 años, pulsos femorales simétricos, gammagrafía pulmonar normal, tomografía informó regresión total del secuestro pulmonar. Conclusión: El tratamiento del secuestro pulmonar por cateterismo con los nuevos dispositivos es factible, efectivo y seguro aún en lactantes.


Classic treatment of pulmonary sequestration is by open thoracic surgery, currently there are alternatives treatment such as embolization. Objective: report the percutaneous treatment of pulmonary sequestration in a child. Method: descriptive study. Medical records and catheterization laboratory database. Results: an infant of 1.5 months in whom was performed treatment of symptomatic extralobar giant pulmonary sequestration by catetherization through implant a vascular plug device from femoral artery. As complications, there was a decrease in the femoral pulse that was treated with enoxaparin and also a systemic inflammatory response syndrome that required intensive care. Time of stay: 10 days. Follow-up: 2 years, symmetrical femoral pulses, normal lung scan, CT scan reported total regression of pulmonary sequestration. Conclusion: The treatmentt of pulmonary sequestration by catheterization with the new devices is feasible, effective and safe even in infants.


Asunto(s)
Humanos , Masculino , Lactante , Cateterismo , Secuestro Broncopulmonar , Embolización Terapéutica
3.
Rev. ecuat. pediatr ; 17(2): 32-33, 12-2016.
Artículo en Español | LILACS | ID: biblio-996590

RESUMEN

El acceso venoso femoral es el abordaje de elección para realizar valvuloplastia y angioplastia en el árbol arterial pulmonar. Objetivo: Comunicar el tratamiento percutáneo de estenosis múltiple de la arteria pulmonar a través de un acceso venoso inusual en un lactante. Método: Estudio descriptivo. Historia clínica y base de datos del laboratorio de cateterismo. Resultados: paciente con trombosis de venas femorales a quien se le realizó valvuloplastia pulmonar, angioplastia de tronco arterial y origen de ambas ramas arteriales pulmonares de forma efectiva con catéteres balón de tamaño progresivo a través de la vena yugular interna derecha en un solo tiempo. Conclusión: El acceso venoso yugular para intervenciones percutáneas en el árbol arterial pulmonar es factible y seguro aún en lactantes.


The femoral venous access is the approach of choice for valvuloplasty and angioplasty in the pulmonary arteries. Objective: we report the percutaneous treatment for multiple pulmonary artery stenosis through an unusual venous approach in an infant. Method: descritve study. Medical records and catheterization laboratory database. Results: patient with femoral veins thrombosis in whom we performed effectively pulmonary valvuloplasty and angioplasty of pulmonary trunk and both branches of the pulmonary artery with progressive size balloon catheters, through the right internal jugular vein during the same procedure. Conclusion: The approach from internal jugular vein for percutaneous interventions in pulmonary trunk and its branches is feasible and safe even in infants.


Asunto(s)
Humanos , Femenino , Lactante , Cateterismo Cardíaco , Valvuloplastia con Balón , Estenosis de Arteria Pulmonar , Venas Yugulares
4.
Rev. ecuat. pediatr ; 17(2): 36-38, 12-2016.
Artículo en Español | LILACS | ID: biblio-996594

RESUMEN

Los laboratorios de cateterismo o salas de hemodinamia localizados en países sudamericanos son escasos y más aún en ciudades en altas alturas. OBJETIVO: comunicar los resultados de un laboratorio de cateterismo de un hospital pediátrico público de tercer nivel andino localizado a 2860 metros sobre el nivel del mar. MÉTODO: estudio retrospectivo, descriptivo y corte transversal. Periodo: 2012 ­ 2016. Base de datos del laboratorio de cateterismo. RESULTADOS: se realizaron 711 procedimientos en 632 pacientes. Edad: mediana 4 años (rango: 0,002-17,8). Peso: mediana 13,7 kg (rango: 1,3-63,6). Género: femenino 57,9%, masculino 42,1%. Tipos de cateterismos: diagnósticos 63,3%, intervencionistas 38,2%. Complicaciones mayores y menores: 2,9 y 3.0% respectivamente, procedimientos sin complicaciones 94,1%. CONCLUSIONES: en este joven laboratorio de cateterismo pediátrico andino la mayoría de procedimientos fueron diagnósticos. El cierre del conducto arterioso persistente fue la intervención más frecuente. La tasa de complicaciones fue baja, comparable a la comunicada por otros grupos.


Pediatric catheterization laboratories in South American countries are scarce and these are located at high altitude even less OBJECTIVE: Report the results of pathologies treated in a catheterization laboratory of an andean public tertiary pediatric hospital which is located 2860 meters above sea level. METHOD: retrospective, descriptive and cross-sectional study. Period: 2012-2016. Data base of catheterization laboratory. RESULTS: 711 procedures in 632 patients were performed. Age: median 4 years (range: 0.002-17.8). Weight: median 13.7 kg (range: 1.3-63.6). Gender: female 57.9%, male 42.1%. Types of catheterizations: diagnostics 63.3%, interventional 38.2%. Major and minor complications: 2.9 and 3.0% respectively, procedures without complications: 94.1%. CONCLUSIONS: The majority of procedures were diagnostic type in this young Andean pediatric catheterization laboratory. The closure of patent ductus arteriosus was the most frequent intervention. The rate of complications was low, similar to those reported by other centers.


Asunto(s)
Humanos , Preescolar , Cateterismo Cardíaco , Cardiopatías Congénitas , Altitud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...